Advances in Analytical Chemistry

Advances in Analytical Chemistry is a peer-reviewed research journal that is devoted to the dissemination of new and original knowledge in all branches of analytical chemistry. The journal publishes features and news articles about major advances, trends, and challenges in analytical chemistry. These articles include peer-reviewed features written by researchers and news stories that discuss novel analytical concepts and instruments.


Andrzej Lewenstam

Editorial Board Member of Advances in Analytical Chemistry

Professor, Abo Akademi University, Center for Process Analytical Chemistry and Sensor Technology 'ProSens', Finland

Research Areas

Sensor Technology, Analytical Chemistry, Clinical Chemistry, Philosophy Of Science

Education

1987D.ScUniveristy of Warsaw, Poland
1977Ph.DUniveristy of Warsaw, Poland
1972M.ScUniveristy of Warsaw, Poland

Experience

2003Associate Professor, Laval University, Quebec City, Canada
1998Principal Scientific Advisor, Thermo Fisher Scientific, (USA/Finland)
1997Director of the Center for Process Analytical Chemistry and Sensor Technology 'ProSens' at Åbo, Akademi University
1993Full Professor at AGH-University of Science and Technology, Cracow, Poland
1990Full Professor of Sensor Technology, Åbo Akademi University, Finland
1985-1997R&D Manager, KONE Corporation, Instrumental Division, Espoo, Finland

Academic Achievement

Chaiman of the Scientific Divison Working Group on Ion Sensitive Sensors and Biosensors, International Federation of Clinical Chemistry (IFCC); 2006
Winner of the "Finnish Industry Innovation Award" 2002
The first Honorary Member of the Polish Magnesiological Society, 1996

Publications: Journals

[1]  A.Hulanicki and A.Lewenstam, Talanta, 1976, 23, 661 665; "Diffusion layer model for copper solid state chalcocite membrane electrode. Sensitivity to copper(II) ions", publisher: Pergamon Press, Great Britain;
[2]  A.Hulanicki, R.Lewandowski and A.Lewenstam, Analyst, 1976, 101, 939 942; "Elimination of ionic interferences in the determination of sulphates in water using the lead sensitive ion selective electrode", publisher: The Chemical Society, Great Britain;
[3]  A.Hulanicki and A.Lewenstam, Talanta, 1977, 24, 171 175; "Interpretation of selectivity coefficient of solid state ion selective electrodes by means of diffusion layer model", publisher: Pergamon Press, Great Britain;
[4]  A.Hulanicki and A.Lewenstam, "Interpretation of response mechanism of solid state ion selective electrodes regarding diffusion processes", in: "Ion selective electrodes", pp. 395 402, publisher: Elsevier, The Netherlands, 1977;
[5]  A.Hulanicki, A.Lewenstam and M.Maj-Zurawska, Analytica Chimica Acta, 1979, 107, 121 128; "Behaviour of iodide ion selective electrodes at low concentration of iodide", publisher: Elsevier, The Netherlands;
[6]  A.Hulanicki, R.Lewandowski and A.Lewenstam, Analytica Chimica Acta, 1979, 110, 197 202; "The mechanism of the potential response of bromide selective electrodes based on mercury salts", publisher: Elsevier, The Netherlands;
[7]  A.Lewenstam, Poznan Studies in the Philosophy of Science, 1980, 4, 272 287; "Models of Atom. Remarks on the development of Science", publisher: Gruner, The Netherlands;
[8]  E.Ghali, B.Dandapani and A.Lewenstam, Surface Technology, 1981, 12, 265 268; "Anodic dissolution of copper(II) sulphide", publisher: Elsevier, Switzerland;
[9]  A.Hulanicki and A.Lewenstam, Analytical Chemistry, 1981, 53, 1401 1405; "Model for treatment of selectivity coefficients for solid state electrodes", publisher: American Chemical Society, USA;
[10]  A.Lewenstam and E.Ghali, "Anodic behaviour of synthetic copper(II) sulphide", in: "Ion selective electrodes", pp. 235 240, publisher: Elsevier, The Netherlands, 1981;
[11]  A.Hulanicki and A.Lewenstam, Talanta, 1982, 29, 661 665; "The variability of selectivity coefficients of solid state ion selective electrodes", publisher: Pergamon Press, Great Britain;
[12]  E.Ghali, B.Dandapani and A.Lewenstam, Journal of Applied Electrochemistry, 1982, 12, 367 382; "Electrodissolution of covellite", publisher: Chapman and Hall, Great Britain;
[13]  J.M.Zytkow and A.Lewenstam, Philosophical Studies, 1982, 9, 39 65; "Is Lavoisier theory better than the phlogistic one?", publisher: Scientific Publishing Comp. (PWN), Poland, (in Polish: 100P/in English: 100E);
[14]  A.Hulanicki, T.Krawczynski and A.Lewenstam, Analytica Chimica Acta, 1984, 158, 343 355; "Effect of some chelating ligands on response of chalcocite copper ion selective electrode", publisher: Elsevier, The Netherlands;
[15]  A.Lewenstam, "The response mechanism of copper ion selective electrode in the presence of halides and organic ligands", in: "Ion selective electrodes in medicine and physiology", pp.24 28, publisher: Springer Verlag, West Germany, 1985;
[16]  A.Lewenstam, T.Sokalski and A.Hulanicki, Talanta, 1985, 32, 531 537; "Anionic interferences with copper ion selective electrodes. Elimination of chloride and bromide interference", publisher: Pergamon Press, Great Britain;
[17]  A.Hulanicki, A.Lewenstam and T.Sokalski, "The behaviour of copper ion selective electrode in the presence of some interfering anions", in: "Ion selective electrodes, 4"' Ed.E.Pungor, pp.459 468, publisher: Elsevier, The Netherlands, 1985;
[18]  A.Hulanicki, R.Lewandowski, A.Lewenstam, M.Chmurska and H. Matuszak, Microchimica Acta, 1985, III, 253 264; "The study of titration conditions in the aluminum and beryllium fluoride systems", publisher: Springer Verlag, Austria;
[19]  A.Lewenstam, A.Ivaska and E.Wänninen, Talanta, 1986, 33, 739 742; "Single point titration of metal and ligands by measuring change in pH", publisher: Pergamon Press, Great Britain;
[20]  A.Lewenstam and J.M.Zytkow, Fresenius Zeitschrift fur Analytische Chemie, 1987, 326, 308 313; "Is Analytical Chemistry an autonomous field of Science?", publisher: Springer Verlag, West Germany;
[21]  A.Lewenstam, A.Hulanicki and T.Sokalski; Analytical Chemistry, 1987, 59, 1539 1544; "Response mechanism of solid state ion selective electrodes in the presence of interfering ions", publisher: American Chemical Society, USA;
[22]  A.Lewenstam, K-S. Saarinen and A.Hulanicki, "Theoretical and practical aspects of ISE selectivity in clinical analysis", in: "Methodology and clinical applications of ion selective electrodes", publisher: International Federation of Clinical Chemistry, The Netherlands, 1987, pp. 151 161;
[23]  A.Hulanicki, T.Sokalski and A.Lewenstam, Analytical Chemistry (Pol.), 1987, 32, 601 607; "Potentiometric determination of copper plating baths", publisher: Scientific Publishing Comp. (PWN);
[24]  A.Hulanicki, T.Sokalski and A.Lewenstam, Microchimica Acta, 1988, III, 119 129; "Side effects in measurements of selectivity coefficients of solid state ion selective electrodes", publisher: Springer Verlag, Austria;
[25]  J.M.Zytkow and A.Lewenstam, Philosophical Studies, 1989, 12, 173 179; "The roles of models in Science", publisher: Scientific Publishing Comp. (PWN), Poland, (in Polish/in English: summary);
[26]  A.Lewenstam and J.M.Zytkow, "Model based science of ion selective electrodes", in: "Ion selective electrodes, 5", Ed. E.Pungor, publisher: Elsevier, The Netherlands, 1989, pp. 297 304;
[27]  A.Hulanicki, T.Sokalski and A.Lewenstam, "The study of processes influencing apparent selectivity for solid-state ion-selective electrodes", in: "Ion selective electrodes, 5", Ed. E.Pungor, publisher: Elsevier, The Netherlands, 1989, pp. 411 423;
[28]  A.Lewenstam, Fresenius Journal of Analytical Chemistry, 1990, 337, 518 521; "Electrochemical measurements in clinical chemistry", publisher: Springer Verlag, West Germany;
[29]  A.Hulanicki, R.Lewandowski , A.Michalska and A.Lewenstam, Analytica Chimica Acta, 1990, 233, 269 274; "Potentiometric method for the determination of total calcium in blood serum", with: A.Hulanicki, R.Lewandowski and A. Michalska, publisher: Elsevier, The Netherlands;
[30]  M.Maj-Zurawska and A.Lewenstam, Analytica Chimica Acta, 1990, 236, 331 335; "Fully automated potentiometric determination of ionized magnesium in blood serum", publisher: Elsevier, The Netherlands;
[31]  A.Lewenstam, "Electrochemical measurements in clinical chemistry", in: "Bioelectrical signals", Eds. M.Nalecz and Wl.Torbicz, publisher: International Center of Biocybernetics, Poland, 1990, pp. 125 134;
[32]  W.Matuszewski , M.Trojanowicz and A.Lewenstam, Electroanalysis, 1990, 2, 607 615; "Elimination of interferences in flow injection amperometric determination of glucose in blood serum using immobilized glucose oxidase", publisher: VGH, USA;
[33]  A.Lewenstam and A.Hulanicki, Selective Electrode Reviews., 1990, 12, 161 201 and 1991, 13, 129-131 (erratum); "Selectivity of ion selective electrodes"; publisher: Pergamon Press, Great Britain;
[34]  J.M.Zytkow and A.Lewenstam, Fresenius Journal of Analytical Chemistry, 1990, 338, 225 233; "Analytical chemistry the science of many models", publisher: Springer Verlag, West Germany;
[35]  A.Lewenstam, A.Hulanicki and E.Ghali, "The role of surface processes in signal formation with solid state ion selective electrodes", in: "Contemporary electroanalytical chemistry", Eds. A.Ivaska, A.Lewenstam, R.Sara, publisher: Plenum Press, Great Britain, 1990, pp. 213-222;
[36]  A.Hulanicki, T.Sokalski and A.Lewenstam, "Potentiometric determination of copper in various plating baths", in: Contemporary electroanalytical chemistry", Eds. A.Ivaska, A.Lewenstam, R.Sara, publisher: Plenum Press, USA, 1990, 145-148;
[37]  A.Lewenstam, M.Maj-Zurawska, N.Blomqvist and K-S.Saarinen, "Automated measurement of ionized magnesium with magnesium ISE", in: "Methodology and clinical applications of ion selective electrodes", publisher: International Federation of Clinical Chemistry, The Netherlands, 1990, pp. 269-278;
[38]  A.Lewenstam, Analytical Proceedings, 1991, 28, 106-109; "Ion selective electrodes in clinical chemistry"; publisher: Royal Chemical Society, Great Britain;
[39]  A.Lewenstam, A.Hulanicki and M.Maj-Zurawska, Electroanalysis, 1991, 3, 727-734; "Application of ion-selective electrodes in clinical analysis"; publisher: VGH, USA;
[40]  A.Lewenstam, M.Maj-Zurawska and N.Blomqvist, Magnesium Bulletin (Pol), 1991, 2, 14-15; "Automated determination of ionized magnesium in blood serum", publisher: Polish Magnesiological Society, Poland, (in Polish);
[41]  M.Trojanowicz, J.Szpunar-Lobinska, A.Moszczynska, E.Lange-Moroz and A. Lewenstam, "Elimination of interferences in amperometric glucose determination in blood serum", in: "Artificial pancreas and drug delivery system", publisher: International Center of Biocybernetics, Poland, 1991;
[42]  M.Trojanowicz, W.Matuszewski and A.Lewenstam, "Elimination of interferences in glucose determination in blood serum using flow-injection amperometry", in: "Flow injection analysis based on enzymes and antibodies", publisher: VCH, Germany, 1991, pp. 160-163, ISBN 3-527-28249-1;
[43]  A.Cadogan, A.Lewenstam and A.Ivaska, Talanta, 1992, 39, 617-620; "Anionic responses of electrochemically synthetised polypyrrole films", publisher: Pergamon Press, Great Britain;
[44]  A.Cadogan, Z.Gao, A.Lewenstam, A.Ivaska and D.Diamond; Analytical Chemistry, 1992, 64, 2496-2501; "All solid-state sodium-selective electrode based on a calixarene ionophore in a PVC membrane with a polypyrrole solid contact", publisher: American Chemical Society, USA;
[45]  A. Lewenstam and J.Öst, "Time-dependent selectivity of ion-selective elctrodes used in clinical analysis", in: "Methodology and clinical application of ion-selective electrodes", publisher: International Federation of Clinical Chemistry, Japan, 1992, pp. 147-156;
[46]  W.R.Kulpmann, T.Kallien and A.Lewenstam, "Evaluation of an ion-selective electrode for the determination of ionized magnesium", in: "Electrolytes, Blood Gases, and Other Critical Analytes", P.D'Orazio, M.F. Burritt and S.F.Sena (Eds); publisher: AACC, USA, 1992, pp. 188-211;
[47]  St.Glab, M.Maj-Zurawska, A.Hulanicki and A.Lewenstam, Analytica Chimica Acta, 1993, 273, 493-497; "Ion-selective electrode control based on coulometrically determined stability constants of biologically important calcium and magnesium complexes", publisher: Elsevier, The Netherlands;
[48]  A.Lewenstam, N.Blomqvist and J.Öst, Kliin Lab, 1993, 10 (2a), 60-63; "Determination and significance of ionized magnesium", publisher: Finnish Society for Clinical Chemistry; ISSN 0782-1549;
[49]  A.Lewenstam, E.Erkola and A.Lehmenkuhler, Fresenius Journal of Analytical Chemistry, 1993, 346, 577-579; "Studies of quartenary ammonium ion influence on potassium ISE", publisher: Springer Verlag, West Germany;
[50]  A.Lewenstam, M.Maj-Zurawska, N.Blomqvist and J.Öst, Clinical Chemistry and Enzymology Communications, 1993, 5, 95-103; "Ionized magnesium-a new parameter in clinical analysis", publisher: Harwood Academic Publishers, USA;
[51]  A.Michalska, A.Lewenstam, A.Ivaska and A.Hulanicki, Electroanalysis, 1993, 5, 261-263; "Study of polypyrrole film as redox electrode", publisher: VCH, USA;
[52]  A.Michalska, A.Hulanicki, K.Dolowy and A.Lewenstam, Analytical Chemistry (Pol), 1993, 38, 385-394; "Critical comparison of the methods for determination of total calcium in blood serum", publisher: Scientific Publishing Company (PWN), Poland, ISSN 0009-2223;
[53]  J.Bobacka, A.Lewenstam and A.Ivaska, Talanta, 1993, 40, 1437-1444; "Potentiometric response of poly(3-octylthiophene), poly(3-methylthiophene) and polythiophene in aqueous solutions", publisher: Pergamon Press, Great Britain;
[54]  M.Maj-Zurawska, A.Hulanicki, D. Drygieniec, M.Pertkiewicz, M.Krokowski, A.Zebrowski and A.Lewenstam, Electroanalysis, 1993, 5, 713-717; "Ionized and total magnesium level in blood serum and plasma of healthy and ill adults"; publisher: VCH, USA;
[55]  M.Trojanowicz, W.Matuszewski, B.Szczepanczyk and A.Lewenstam, "Clinical application of biosensing with amperometric detection of ammonia-nitrogen", in: "Uses of Immobilized Biological Compounds", G.Guilbault and M.Mascini, eds; publisher: Kluwer Academic Press, The Netherlands, 1993, pp. 141-150, ISBN 0-7923-2529-X;
[56]  Z.Gao, J.Bobacka, A.Lewenstam and A.Ivaska, Synthetic Metals, 1994, 62, 117-123; "Electrochemical properties of polypyrrole polymerized in methylene blue solution", publisher: Elsevier, The Netherlands;
[57]  Z.Gao, J.Bobacka, A.Lewenstam and A.Ivaska, Electrochimica Acta, 1994, 39, 755-762; "Electrochemical behaviour of polypyrrole film polymerized in indigo carmine solution", publisher: Pregamon Press, Great Britain;
[58]  A.Hulanicki, A.Michalska, and A.Lewenstam, Talanta, 1994, 41, 323-325; "Bifunctionality of chemical sensors based on the conducting polymer polypyrrole", publisher: Pergamon Press, Great Britain;
[59]  A.Lewenstam, J.Bobacka and A.Ivaska, Journal Electroanalytical Chemistry, 1994, 368, 23-31; "Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part I. Theory", publisher: Elsevier, Switzerland;
[60]  J.Bobacka, Z.Gao, A.Ivaska and A.Lewenstam, Journal of Electroanalytical Chemistry, 1994, 368, 33-41; "Mechanism of ionic and redox sensitivity of p-type conducting polymers. Part II. Experimental study of polypyrrole", publisher: Elsevier, Switzerland;
[61]  A.Lewenstam, The Scandinavian Journal of Clinical & Laboratory Investigation, 1994, 54, 11-20; "Design and pitfalls of ion-selective electrodes", publisher: Blackwell Scientific Publications, Great Britain;
[62]  A.Lewenstam, N.Blomqvist and J.Öst, The Scandinavian Journal of Clinical & Laboratory Investigation, 1994, 54, 37-44; "Characterization, standardization and experiences with KONE ISE for Mg2+", publisher: Blackwell Scientific Publications; Great Britain;
[63]  M.Maj-Zurawska, M.Pertkiewicz, A.Hulanicki, and A.Lewenstam, "The investigation of ionized magnesium in human serum and plasma using ISE", in: "Magnesium 1993", S.Golf, D.Dralle and L. Vecchiet, Eds., publisher: John Libbey, Great Britain, 1994, pp.65-69, ISBN 0 86196 360 1;
[64]  W.Matuszewski, M.Trojanowicz, A.Lewenstam, A.Moszczynska and E.Lange-Moroz, Analytical Sciences, 1994, 10, 423-428; "Amperometric glucose biosensor for undiluted whole blood analysis", publisher: Japan Chemical Society, Japan;
[65]  T. Krawczynski, M.Trojanowicz and A.Lewenstam, Talanta, 1994, 41, 1229-1236; "Enzymatic flow-injection determination of urea in blood serum using potentiometric gas sensor with internal nonactin based ISE", publisher: Pergamon Press, Great Britain;
[66]  A.Hulanicki, A.Michalska and A.Lewenstam, Electroanalysis, 1994, 6, 604-605; "Observed redox interferences on polypyrrole-based perchlorate selective electrode", publisher: VCH, USA;
[67]  J.Bobacka, M.McCarrick, A.Lewenstam and A.Ivaska, Analyst, 1994, 119, 1985-1991; "All-solid poly(vinylchloride) ion-selective electrodes using poly(3-octylthipohene) as solid internal contact", publisher: The Royal Chemical Society, Great Britain;
[68]  A.Hulanicki, A.Lewenstam and M.Maj-Zurawska, "Magnesium: clinical significance and analytical determination", in: "Reviews on Analytical Chemistry", D.Littlejohn and D.T.Burns, Eds; publisher. The Royal Chemical Society, Great Britain, 1994, pp.317-325, ISBN 0-85186-982-3;
[69]  A.Michalska, A.Hulanicki and A.Lewenstam, Analyst, 1994, 119, 2417-2420; "All-solid state H+ selective electrode based on conducting poly(pyrrole) solid contact", publisher: The Royal Chemical Society, Great Britain;
[70]  D.Diamond, E.McEnroe and A.Lewenstam, Electroanalysis, 1994, 6, 962-971; "Evaluation of a new reference electrode junction material for ISEs", publisher: VCA, USA;
[71]  A.Hulanicki and A.Lewenstam, Egyptian Journal of Analytical Chemistry, 1994, 3(2), 12-16; "Ion-selective electrodes for measurements of calcium and magnesium in clinical analysis", publisher: Egyptian Chemical Society, Egypt;
[72]  A.Lewenstam, A.Michalska and A.Ivaska; Analytical Chemistry (Pol); 1995, 40, 587-597; "Potentiometric response of polypyrrole films doped with hexacyanofferate (II) ions", publisher: Polish Scientific Publishing Company, PWN, ISSN 0009-2223;
[73]  J.Bobacka, M. McCarrick, A.Ivaska and A.Lewenstam, Analytical Chemistry, 1995, 67, 3819-3823; "Single-piece all-solid-state ion-selective electrode", publisher: American Chemical Society, USA;
[74]  A.Lewenstam, Foundations of Science, 1995, 1(2), 209-211; "Focus the cognitive modeling to real scientists", publisher: Kluver, The Netherlands; ISSN 1233-1821;
[75]  T.Sokalski, D.Paradowski, J.Ostaszewska, M.Maj-Zurawska, J.Mieczkowski, A.Lewenstam and A.Hulanicki, "Observations on the behaviour of some trifluoroacethophenone derivates as neutral carriers for carbonate ion-selective electrodes", Analyst, 1996, 121, 133-138; publisher: The Royal Chemical Society, Great Britain;
[76]  M.Trojanowicz, A.Lewenstam, T.Krawczynski, I.Lahdesmaki and W.Szczepek; Electroanalysis, 1996, 8, 233-243; "Flow injection amperometric detection of ammonia using polypyrrole-modified electrode and its application in urea and creatinine biosensors", VCA, USA;
[77]  M.Maj-Zurawska and A.Lewenstam, Magnesium Bulletin (Pol), 1996, 7, 34-38; "Ionized magnesium as a new parameter in clinical analysis", publisher: Polish Magnesiological Society, Poland, (in Polish);
[78]  I.Lahdesmäki, A.Lewenstam and A.Ivaska, Talanta, 1996, 43, 125-134; "Polypyrolle-based amperometric ammonia sensor", publisher: Pergamon Press, Great Britain;
[79]  J.Migdalski, T.Blaz and A.Lewenstam, Analytica Chimica Acta, 1996, 322, 151-159; "Conducting polymer based ion-selective electrodes", publisher: Elsevier, The Netherlands,
[80]  A.Lewenstam, The Scandinavian Journal of Clinical & Laboratory Investigation, 1996, 56, 135-140; "Electric potential measured, concentration reported: how to get mmols from mV", publisher: Blackwell Scientific Publication, Great Britain;
[81]  T. Krawczynski vel Krawczyk, M.Trojanowicz, A.Lewenstam and A.Moszczynska, Biosensors & Bioelectronics, 1996, 11, 1155-1165; "Lactate solid-state biosensor with multilayer of electrodeposited polymers for flow-injection clinical analysis", publisher: Elsevier, Great Britain;
[82]  T.Lindfors, J.Bobacka, A.Lewenstam and A.Ivaska, Analyst, 1996, 121, 1871; "An impedance spectroscopic study on single-piece all-solid-state calcium-selective electrode based on polyaniline", publisher: The Royal Chemical Society, Great Britain;
[83]  A.Lewenstam, J.Bobacka and J.Öst, "Electrochemical sensors in clinical and environmental analysis-state-of-the-art", in: "Chemistry Forum '97", pp. 11-13, ISBN 83-904741-1-5, publisher: Editing Office TUW, Warsaw, 1997, Poland;
[84]  R.W.Burnett, A.K.Covington, N.G. Fogh-Andersen, W.Kulpman, A.Lewenstam, A.J.H.Maas, O.Muller-Plathe, A.L.VanKessel, W.G.Zijlstra;Journal of the International Federation of Clinical Chemistry, 1997, 9(1), 16-22; "Use of ion-selective electrodes for blood-electrolyte analysis", publisher: INC Inc. , USA;
[85]  M.Maj-Zurawska, T.Sokalski, J..Ostaszewska, D.Paradowski, J.Mieczkowski, Zb. Czarnocki, A.Lewenstam and A.Hulanicki; Talanta, 1997, 44, 1641-1647; "Carbonate ion-selective electrode with trifluoroacetophenone derivatives in potentiometric clinical analyzer", publisher: Elsevier, Great Britain;
[86]  A.Michalska and A.Lewenstam; "Potentiometric selectivity of poly(pyrrole) films", in: "Chemical and biological sensors and analytical electrochemical methodes", Eds. A.J.Ricco, M.A. Butler, P.Vanysek, G.Horvaiand and A.F.Silva, The Electrochemical Society Proceedings Volume 97-19, Pennington, USA, pp. 514-523, ISBN 1-56677-147-1;
[87]  A.Michalska, A.Ivaska and A.Lewenstam, Analytical Chemistry, 1997, 69, 4060-4064; "Modeling potentiometric sensitivity of conducting polymers", publisher: American Chemical Society, USA;
[88]  K.Mikhelson and A.Lewenstam; "Improvement of potentiometric selectivity of ion-exchanger based membranes doped with co-exchanger. Origin of the effect", in: "Eurosensors XI. The 11th European Conference on Solid-State Transducers", Warsaw, Poland, 21-24.09.1997, pp. 329-332, (1P3-7), ISBN 83-908335-0-6;
[89]  A.Michalska, A.Hulanicki and A.Lewenstam; "Conducting poly(pyrrole) membranes in potentiometry", in: "Eurosensors XI. The 11th European Conference on Solid-State Transducers", Warsaw, Poland, 21-24.09.1997, pp. 361-364 (1P3-15), ISBN 83-908335-0-6;
[90]  K.Maksymiuk, A-S.Nyback, J.Bobacka, A.Ivaska and A.Lewenstam, Journal od Electroanalytical Chemistry, 1997, 430, 243-252; "Mettalic and non-metallic redox response of conducting polymers", publisher: Elsevier, Great Britain;
[91]  A.Michalska, A.Hulanicki and A.Lewenstam, Microchemical Journal, 1997, 57, 59-64; "All-solid-state potentiometric sensors for potassium and sodium based on poly(pyrrole) solid contact", publisher: Springer Verlag, Austria;
[92]  K.N.Mikhelson and A.Lewenstam, Sensors and Actuators, 1998, 42, 345-351; "Improvement of potentiometric selectivity of ion-exchanger based membranes doped with co-exhanger. Origin of the effect", publisher: Elsevier, The Netherlands;
[93]  T.Lindfors, J.Bobacka, A.Lewenstam and A.Ivaska, Electrochimica Acta, 1998, 43, 3503-3509; "Study on soluble polypyrrole as a component in all-solid-state ion-sensors", publisher: Elsevier, Great Britain;
[94]  T.Lindfors, P.Sjoberg, J.Bobacka, A.Lewenstam and A.Ivaska, Analytica Chimica Acta, 1999, 385, 163-173; "Characterization of single-piece all-solid-state lithium-selective electrode based on soluble conducting polyaniline", publisher: Elsevier, The Netherlands;
[95]  J.Bobacka, A.Ivaska and A.Lewenstam, Analytica Chimica Acta, 1999, 385, 195-202; "Plastisizer-free all-solid-state potassium electrode based on poly(3-octhylthiophene) and valinomycin", publisher: Elsevier, The Netherlands,
[96]  S.E.Didina, O.P.Chogin, K.N.Mikhelson and A.Lewenstam, Vestnik S.Peterburgskogo Universiteta, 1999, 4(2/11), 39-44; "Response of calcium-selective membranes to changes of pH in calcium chloride solutions, role of the diffusion potential in membranes", publisher: Nauka, Russia (in Russian);
[97]  A-S. Nybäck, A.Ivaska and A.Lewenstam, Analytical Chemistry (Pol), 1999, 44, 405-411; "Potentiometric properties of polypyrrole films with calgamite", publisher: The Polish Academy of Science, Poland;
[98]  E.Bakker, D.Diamond, A.Lewenstam and E.Pretsch, Analytica Chimica Acta, 1999, 393, 11-18; "Ion sensors. Current limits new trends", publisher: Elsevier, The Netherlands;
[99]  O.Hyokyvirta, P.Pohjanne, A.Heinavaara, J.Hirvonen and A.Lewenstam, "The corrosion of titanium and some other construction materials during hydrogen peroxide bleaching according to the field measurements", in: "Environmental Degradation of Materials and Corrosion Control in Metals", Eds. M.Elboujdaini and E.Ghali, pp. 205-222, CIMMP Canada, 1999; ISBN 0-919086-95-0.
[100]  J.Migdalski, T. Blaz and A. Lewenstam, Analytica Chimica Acta, 1999, 395, 65-75; "Electrochemical deposition and properties of polypyrrole films doped with calcion ligands", publisher: Elsevier, The Netherlands.
[101]  T.Sokalski, M.Maj-Zurawska, A.Hulanicki and A.Lewenstam, Electroanalyisis, 1999, 9, 632-636; "Optimization of a reference electrode with constrained liquid junction for the measurements of ions", publisher: VCH, USA.
[102]  J.Migdalski, T.Blaz, Z.Kowalski and A. Lewenstam, Electroanalysis, 1999, 11, 735-743; "Non-classical indicator electrodes with dual sensitivity", publisher: VCH, USA.
[103]  K. N. Mikhelson, A.Lewenstam and S. E. Didina, Electroanalysis, 1999, 11, 793-798; "Contribution of the diffusion potential into the membrane potential and into the ion-selective electrode response", publisher: VCH, USA.
[104]  P.Sjoberg, J.Bobacka, A.Lewenstam and A.Ivaska, Electroanalysis, 1999, 11, 821-824; "All-solid-state chloride-selective electrode based on poly(3-octhylthiophene) and tridodecylmethylammonium chloride", publisher: VCH, USA.
[105]  A.Michalska and A.Lewenstam, Analytica Chimica Acta, 2000, 406, 159-169, "Potentiometric selectivity of p-doped polymer films", publisher: Elsevier, The Netherlands.
[106]  N-E. L. Saris, E. Mervaala, H. Karppanen, J. A. Khawaja, A. Lewenstam, Clinica Chimica Acta, 2000, 294, 1-26; "Magnesium-an update on physiological, pathological and analytical aspects"; publisher: Elsevier, The Netherlands,
[107]  K.Maksymiuk, J.Bobacka, A.Ivaska and A.Lewenstam, Analytical Letters, 2000, 33, 1339-1360; "Coupled redox and pH potentiometric responses of electrodes coated with polypyrrole", publisher: Wiley & Sons, USA;
[108]  T. Blaz, J. Migdalski and A. Lewenstam, Talanta, 2000, 52, 319-328; "Poly(pyrrole)-based calcium sensor as an indicator electrode in potentiometric titrations", publisher: Elsevier, The Netherlands;
[109]  I.Lahdesmaki, A.Ivaska, A.Lewenstam and W.W.Kubiak, Talanta, 2000, 52, 269-275; "Interferences in polypyrrole-based amperometric ammonia sensor", publisher: Elsevier, The Netherlands;
[110]  Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AHJ, Müller-Plathe O, Van Kessel AL, Zijlstra WG., Clinical Chemistry and Laboratory Medicine, 2000, 38, 363-370; "Use of Ion-Selective Electrodes for Blood-Electrolyte Analysis. Recommendations for Nomenclature, Definitions and conventions", publisher: Walter de Gruyter, Germany-USA;
[111]  K. N. Mikhelson and A.Lewenstam, Analytical Chemistry, 2000, 72, 4965-4972; "Modeling of divalent/monovalent ion selectivity of ion-exchanger membranes doped with co-exchanger", publisher: American Chemical Society, USA;
[112]  J.Bobacka, A.Lewenstam and A.Ivaska, Journal Electroanalytical Chemistry, 2000, 489 17-27; "Electrochemical a.c. impedance study of oxidized poly(3, 4-ethylenedioxytiophene) in aqueous solutions", publisher: Elsevier, The Netherlands;
[113]  Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AHJ, Müller-Plathe O, Van Kessel AL, Zijlstra WG., Clinical Chemistry and Laboratory Medicine, 2000, 38, 1065-1071; "Recommendations for Measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood", publisher: Walter de Gruyter, Germany-USA;
[114]  Burnett RW, Christiansen T, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AHJ, Müller-Plathe O, Sachs Ch, Siggaard-Andersen O, Van Kessel AL, Zijlstra WG Clinical Chemistry and Laboratory Medicine, 2000, 38, 1301-1314; "IFCC recommended method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood", publisher: Walter de Gruyter, Germany-USA;
[115]  T.Sokalski and A.Lewenstam, Electrochemical Communications, 2001, 3, 107-112; "Application of Nernst-Planck and Poisson equations for interpretation of liquid-junction and membrane potentials in real-time and space domains", publisher: Elsevier, The Netherlands;
[116]  A.Ivaska, T.Lindfors, J.Bobacka and A.Lewenstam, Kemia-Kemi, 2001, 2, 90-93; "Solid-contact ion sensors", publisher: Finnish Chemical Society, Finland (in Finnish);
[117]  Burnett RW, Covington AK, Fogh-Andersen N, Külpmann WR, Lewenstam A, Maas AHJ, Van Kessel AL, Zijlstra WG Clinical Chemistry and Laboratory Medicine, 2001, 39, 283-289; "IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasme or serum", publisher: Walter de Gruyter, Germany-USA;
[118]  J.Bobacka, T. Lahtinen, J. Nordman, S.Haggestrom, K.Rissanen, A.Lewenstam and A.Ivaska, Electroanalysis, 2001, 13, 723-726; "All-solid-state Ag+-ISE based on [2, 2, 29p, p, p-cyclophane, publisher: Wiley, USA;
[119]  K.N. Mikhelson, J. Bobacka, A. Lewenstam and A.Ivaska, Electroanalysis, 2001, 13, 876-881; "Potentiometric performance and interfacial kinetics of neutral ionophore based ISE membranes in interfering ion solutions before and after contact with primary ions", publisher: Wiley, USA;
[120]  M.Vazquez, K.Mikhelson, J.Bobacka, A.Ivaska, A.Lewenstam, S.Piepponen, J.Rämö and M.Sillanpää, Electroanalysis, 2001, 13, 1119-1124; "Determination of Na+, K+, Ca2+ and Cl-ions in wood pulp suspension using ion-selective electrodes", publisher: Wiley, USA;
[121]  J.Migdalski, T.Blaz, Z.Kowalski, A.Lewenstam, "Inducing cationic sensitivity of polypyrrole films doped with metal complexing ligands", Annals of the Polish Chemical Society, 2001, S3-A5, pp.35-36, ISBN 83-90-1844-5-1;
[122]  J.Bobacka, A.Lewenstam and A.Ivaska, Journal of Electroanalytical Chemistry, 2001, 509, 27-30; "Equilibrium potential of potentiometric ion sensors under steady-state curent by using current-reversal chronopotentiometry", publisher: Elsevier, The Netherlands;
[123]  R.W.Burnett, P.D'Orazio, N.Fogh-Andersen, K.Kuwa, L.Larsson, A.Lewenstam, A.H.J.Maas, G.Marger and U.Spichiger, Clinica Chimica Acta, 2001, 307, 205-209; "IFCC recommendation on reporting results for blood glucose", publisher: Elsevier, USA;
[124]  N.N.Markuzina, K.N.Mikhelson, E.V.Molodkina and A.Lewenstam, Russian Journal of Applied Chemistry, 2001, 74, 417-421; "K-selective solid contact electrode", . publisher: Nauka, Russia;
[125]  M.Vazquez, J.Bobacka, A.Ivaska and A.Lewenstam, Sensors and Actuators B, 2002, 82, 7-13; "Influence of oxygen and carbon dioxide on the electrochemical stability of poly(3, 4-ethylenedioxythiophene) used as ion-to-electron transducer in all-solid-state ion-selective electrodes", publisher: Elsevier, USA;
[126]  K.N.Mikhelson, J.Bobacka, A.Ivaska and A.Lewenstam, Analytical Chemistry, 2002, 74, 518-527; "Selectivity of lithium electrodes: correlation with ionophore complex stability constants and with interfacial exchange current densitites", publisher: American Chemical Society, USA;
[127]  F.Sundfors, J.Bobacka, A. Ivaska A. Lewenstam, Electrochimica Acta 2002, 47, 2245-2251; "Kinetics of electron transfer bettween Fe(CN)6 3-/4-and poly(3.4-ethylenodioxythiophene) studied by electrochemical impedance spectroscopy", publisher: Elsevier, USA;
[128]  A.L.Grekovich, N.N.Markuzina, K.N.Mikhelson, M.Bochenska and A.Lewenstam, Electroanalysis, 2002, 14, 551-555; "Conventional and solid-contact lithium-selective electrodes based on tris(N, N-dicyclohexylamide) neutral ionophore", publisher: Wiley, USA;
[129]  J.Migdalski, T.Blaz and A.Lewenstam, Analytical Chemistry (Pol). 2002, 47, 371-384; "Inducing cationic sensitivity of polypyrrole films doped with metal complexing agents by chemical and electrochemical methods", publisher: Polish Academy of Science, Poland;
[130]  J.Bobacka, T.Lahtinen, H.Koskinen, K.Rissanen, A.Lewenstam and A.Ivaska, Electroanalysis, 2002, 14, 1353-1357; "Silver ion-selective electrodes based on -coordinating ionophores without heteroatoms", publisher VCH, USA;
[131]  J.Bobacka, T. Alaviuhkola, V. Hietapelto, H. Koskinen, A. Lewenstam, M. Lämsä, J. Pursiainen and A. Ivaska, Talanta, 2002, 58, 341-349; "Solid-contact ion-selective electrodes for aromatic cations based on π-coordinating soft carriers", publisher: Elsevier, The Netherlands;
[132]  J. Bobacka, M.Maj-Zurawska and A.Lewenstam, Biosensors & Bioelectronics, 2003, 18, 245-253; "Carbonate ion-selective electrode with negligible interference from salicylate", publisher: Elsevier, The Netherlands;
[133]  T. Sokalski, P. Lingenfelter and A. Lewenstam, Journal of Physical Chemistry B, 2003, 117, 2443-2452; "Numerical solution of the coupled Nernst-Planck and Poisson equations for liquid-junction and ion-selective membrane potentials", publisher: American Chemical Society;
[134]  J. Bobacka, A. Ivaska and A. Lewenstam, Electroanalysis, 2003, 15, 366-374; "Potentiometric ion sensors based on conducting polymers", publisher: VCH, USA;
[135]  Maj-Zurawska M, Ziemianek D, Mikolajczuk A, Mieczkowski J, Lewenstam A, Hulanicki A, Sokalski T., Journal of Analytical and Bioanalytical Chemistry, 2003, 376 (4), 524-526; "Improved selectivity and detection limit of the carbonate-selective electrode", publisher: Springer Verlag, Germany;
[136]  K. N. Mikhelson, J.Bobacka, A. Lewenstam and A. Ivaska; Russian Journal of Electrochemistry 2003, 39(7), 771-776; "Towards reversibility of the ion transfer across the interface between valinomycin membranes and aqueous electrolyte solutions", publisher: Kluver, The Netherlands;
[137]  J. Migdalski , B. Paczosa, T. Blaz and A. Lewenstam, Microchimica Acta, 2003, 143, 177-185; "Magnesium and calcium-dependent membrane potential of poly(pyrrole) films doped with adenosine triphosphate"; publisher: Springer Verlag, Germany;
[138]  P. Lingenfelter, T. Sokalski and A. Lewenstam, Materials Research Society Symposium Proceedings 2003, 752, 193-198; "Numerical solution of the coupled Nernst-Planck and Poisson equations for ion-selective membrane potentials; ISSN:0272-9172.
[139]  M. Vázquez, J. Bobacka, A. Ivaska and A. Lewenstam, Talanta, 2004, 62, 57-63; "Small-volume radial flow cell for all-solid-state ion-selective electrodes", publisher: Elsevier, Great Britain;
[140]  M.Vázquez, P. Danielsson, J. Bobacka, Andrzej Lewenstam and Ari Ivaska, Sensors & Actuators 2004, 97, 182-189; "Solution-cast films of poly(3, 4-ethylenedioxythiophene) as ion-to-electron transducers in all-solid-state ion-selective electrodes", publisher: Elsevier, Great Britain;
[141]  J. Bobacka, T. Lindfors, A. Lewenstam and A. Ivaska, American Laboratory, 2004, v. 2, 13-20 "All-solid-state ion sensors using conducting polymers as ion-to-electron transducers", ; publisher: ACI, USA;
[142]  J. Bobacka , V. Väänänen, A. Lewenstam, A. Ivaska, Talanta, 2004, 63, 135-138; "Influence of anionic additive on Hg2+ interference on Ag+-ISEs based on [2.2.2]p, p, p-cyclophane as neutral carrier", publisher: Elsevier, Great Britain;
[143]  P. Sjoberg-Erola, J.Bobacka, T.Sokalski, J.Mieczkowski, A. Ivaska, A.Lewenstam, Electroanalysis, 2004, 16, 379-385; "All-solid-state chloride sensors with poly(3-octylthiopene) matrix and trihexadecylammonium chlorides as an ion exchanger salt", publisher: Elsevier, Great Britain;
[144]  B.Paczosa, T. Blaz, J. Migdalski, A. Lewenstam , Polish Journal of Chemistry, 2004, 78, 1543-1552; "Conducting polymers films as model biological membranes. Electrochemical and ion-exchange properties of PPy and PEDOT films doped with heparine". publisher: Polish Chemical Society; Poland;
[145]  A. Konopka, T. Sokalski, A. Michalska, A. Lewenstam and M. Maj-Zurawska; Analytical.Chemistry, 2004, 76, 6410-6418; "Factors Affecting the Potentiometric Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements", publisher: American Chemical Society;
[146]  T.Blaz, J.Migdalski and A.Lewenstam, The Analyst, 2005, 130, 637–643; "Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix", publisher: The Royal Chemical Society, UK;
[147]  M. C. B. Rayana, R. W. Burnett, A. K. Covington, P. D'Orazio, N. Fogh-Andersen, E. Jacobs, W. R. Kulpmann, K. Kuwa, L. Larsson, A. Lewenstam, A. H. J. Maas, G. Mager, J. H. J. Naskalski, A. O. Okorodudu, Ch. Ritter and A. St John; Clinical Chemistry and Laboratory Medicine, 2005, 43(5), 564–569 "Guidelines for sampling, measuring and reporting ionized magnesium in undiluted serum, plasma or blood"; publisher: Walter de Gruyter Berlin, New York; DOI 10.1515/CCLM.2005.098.
[148]  M. Vazquez, J. Bobacka, M. Luostarinen, K. Rissanen, A. Lewenstam and A, Ivaska, Journal of Solid State Electrochemistry, 2005, 9, 312–319; "Potentiometric sensors based on poly(3, 4-ethylenedioxythiophene) (PEDOT) doped with sulfonated calix[4]arene and calix[4]resorcarenes", publisher: Springer Verlag, Germany; DOI 10.1007/s10008-004-0597-7,
[149]  I. Bedlechowicz, T. Sokalski, A. Lewenstam and M. Maj-Zurawska, Sensors and Actuators B: Chemical, 2005, 108, 836-839; "Calcium ion-selective electrodes under galvanostatic current control", publisher: Elsevier, The Netherlands;
[150]  Paul D'Orazio, Robert W. Burnett, Niels Fogh-Andersen, Ellis Jacobs, Katsuhiko Kuwa, Wolf R. Külpmann, Lasse Larsson, Andrzej Lewenstam, Anton H.J. Maas, Gerhard Mager, Jerzy W. Naskalski, Anthony O. Okorodudu:Clinical Chemistry, 2005, 51, 1573-1576; "Approved IFCC Recommendation on Reporting Results for Blood Glucose"; publisher: AACC, USA.
[151]  W. Kucza, M. Danielewski and A.Lewenstam, Ceramics, 2005, 92, 205-210, "Non-stationary diffusion in solid electrolytes: Nernst-Planck-Poisson model" publisher: Polish Academy of Science, Poland; ISBN 83-89541-59-9.
[152]  B. Paczosa-Bator, J. Peltonen, J. Bobacka and A. Lewenstam; Analytica Chimica Acta, 2006, 555, 118-127; "Influence of morphology and topography on potentiometric response of magnesium and calcium sensitive PEDOT films doped with adenosine triphosphate (ATP)", publisher: Elsevier, The Netherlands;
[153]  B. Paczosa J. Migdalski and A. Lewenstam, Electrochimica Acta, 2006, 51, 2173-2181; "Conducting polymer films as model biological membranes. Electrochemical and ion-exchange properties of poly(pyrrole) films doped with asparagine and glutamine" publisher: Elsevier, The Netherlands;
[154]  Kucza, M.Danielewski, A. Lewenstam, Electrochemical impedance modelled by Nernst-Planck-Poisson equations" Electrochemical Communications, 2006, 8/3, 416-420; publisher: Elsevier, The Netherlands;
[155]  Ben Rayana, Burnett RW, Covington AK, D'Orazio P, Fogh-Andersen N, Jacobs E, Kataky R, Külpmann W, Kuwa K, Larsson L, Lewenstam A, Maas AHJ, Mager G, Naskalski JW, Okorodudu AO, Ritter C, St John A. Clinical Chemistry and Laboratory Medicine, 2006, 44, 346–352; "Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood"; publisher: Walter de Gruyter, Berlin, New York, Germany/USA;
[156]  Z. Mousavi, J. Bobacka, A. Lewenstam and A. Ivaska, "Response mechanism of potentiometric Ag+ sensor based on poly(3, 4-ethylene dioxythiophene) doped with silver hexabromocarborane", Journal of Electroanalytical Chemistry, 2006, 593, 219-226; publisher: Elsevier, The Netherlands;
[157]  I. Bedlechowicz-Śliwakowska, P. Lingenfelter, T. Sokalski, A. Lewenstam and M. Maj-Żurawska, "Ion-Selective Electrode for measuring low Ca2+ concentrations in the presence of in high K+, Na+ and Mg2+ background", Journal of Analytical and Bioanalytical Chemistry, 2006, 385, 1477-1482, publisher: Springer-Verlag, Germany;
[158]  P. Lingenfelter, I. Bedlechowicz-Śliwakowska, T. Sokalski, M. Maj-Żurawska and A. Lewenstam, "Time dependent phenomena in the potential response of ion-selective electrodes treated by the Nernst-Planck-Poisson model. 1. Intramembrane processes and selectivity", Analytical Chemistry, 2006, 78, 6783-6791, publisher: American Chemical Society;
[159]  A. Konopka, T.Sokalski, A. Lewenstam and M. Maj-Zurawska, the influence of the conditioning procedure on potentiometric characteristics of solid contact calcium-selective electrodes in nanomolar concentration solutions", Electroanalysis, 2006, 22, 2232-2242, publisher: VCH-Wiley, USA;
[160]  Paul D'Orazio, Robert W. Burnett, Niels Fogh-Andersen, Ellis Jacobs, Katsuhiko Kuwa, Wolf R. Külpmann, Lasse Larsson, Andrzej Lewenstam, Anton H.J. Maas, Gerhard Mager, Jerzy W. Naskalski, Anthony O. Okorodudu; Clinical Chemistry, 2006, 44, 1486-1590; "Approved IFCC recommendation on reporting results for blood glucose"; publisher: Walter de Gruyter, Germany-USA;
[161]  B. Paczosa-Bator, T.Blaz, J. Migdalski and A. Lewenstam, "Conducting polymer films modified by active ligands as model to study propagation of biological membrane potential with time", Bioelectrochemistry 2007, 71, 66-74, publisher: Elsevier, The Netherlands;
[162]  J. Migdalski, T.Blaz and A.Lewenstam, "Application of conducting polymer-based indicator and reference electrodes in junctionless potentiometric determination of copper allows eliminating chloride interference". Analytica Chimica Acta, 2007, 594, 204-210; publisher: Elsevier, The Netherlands.
[163]  P. Sjöberg-Eerola, J. Bobacka, A. Lewenstam and A.Ivaska, "All-solid-state chloride sensors based on electronically conducting, semiconducting and insulating polymer membranes", Sensors and Actuators B, 2007, 127, 545-553; publisher: publisher: Elsevier, The Netherlands.
[164]  M. C. Ben Rayana, R. W. Burnett, A. K. Covington, P. D'Orazio, N. Fogh-Andersen, E. Jacobs, W. R. Külpmann, K. Kuwa, L. Larsson, A. Lewenstam, A. H.J. Maas, G. Mager, J.W. Naskalski, A. O. Okorodudu, Ch.Ritter, A. St John."IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma", Clinical Chemistry and Laboratory Medicine , 2008, 48, 21-26, publisher: Walter de Gruyter, Berlin-New York, Germany-USA.
[165]  R. Filipek, K. Szyszkiewicz, M. Danielewski and A. Lewenstam, "Numerical Method and Analysis of Consistency for Electrodiffusion Problem", in: CP963, Vol. 2 Part A, Computation in Modern Science and Engineering, Proceedings of the International Conference on Computational Methods in Science and Engineering 2007, edited by T. E. Simos and G. Maroulis, publisher: American Institute of Physics 978-0-7354-0478-6/07, pp. 473-476.
[166]  J.Bobacka, A. Ivaska, A. Lewenstam, "Potentiometric ion sensors", Chemical Reviews, 2008, 108, 329-351, publisher: American Chemical Society, USA.
[167]  B. Grysakowski, A. Lewenstam, M. Danielewski, "Electro-Diffusion at Different Length Scales", Diffusion Fundamentals, 2008, 8 4.1–4.7, publisher: The Open-Access Journal for the Basic Principles of Diffusion Theory, Experiment and Application, www.diffusion-fundamentals.org, ISSN 1862-4138;
[168]  M.A. Peshkova, T. Sokalski, K.N. Mikhelson, A. Lewenstam, Obtaining Nerstain response of Ca2+ electrode in a broad concentration range by tuned galvanostatic polarization, Analytical Chemistry, 2008, 80, 9181-9187.
[169]  P. Sjöberg-Eerola, J. Nylund, J. Bobacka, A. Lewenstam, A. Ivaska, Soluble semiconducting poly(3-octylthiophene) as a solid-contact material in allsolid-state chloride sensors, Sensors and Actuators B, 2008, 134, 878-886.
[170]  M. C. Ben Rayana, R. W. Burnett, A. K. Covington, P. D'Orazio, N. Fogh-Andersen, E. Jacobs, W. R. Külpmann, K. Kuwa, L. Larsson, A. Lewenstam, A. H.J. Maas, G. Mager, J.W. Naskalski, A. O. Okorodudu, Ch.Ritter, A. St John."IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma", Clinical Chemistry and Laboratory Medicine, 2008, 48, 21-26.
[171]  G. Lisak, E. Grygolowicz-Pawlak, M. Mazurkiewicz, E. Malinowska, T. Sokalski, J. Bobacka, A. Lewenstam, "New polyacrylate-based lead (II) ion-selective electrodes" Microchimica Acta, 2009, 164, 293-297.
[172]  J.Migdalski, B. Bas, T. Blaz, J.Golimowski and A. Lewenstam, "A miniaturized and integrated galvanic cell for the potentiometric measurement of ions in biological liquids" Journal of Solid State Electrochemistry, 2009, 13, 149-155.
[173]  R. Filipek, K. Szyszkiewicz-Warzecha, B. Bożek, M. Danielewski and A. Lewenstam, "Diffusion transport in electrochemical systems; A new approach to determining of the membrane potential at steady state", Def. and Diff. Forum, 2009 283-286, 487-493.
[174]  B.Paczosa-Bator, M. Stepien, M. Maj-Zurawska and A. Lewenstam, "Biomimetic study of the Ca2+-Mg2+ and K+-Li+ antagonism on biologically active sites: new methodology to study potential dependent ion exchange", Magnesium Research 2009, 22, 10-20.
[175]  A. Lewenstam, T. Sokalski, J. Jasielec, W. Kucza, R. Filipek, B. Wierzba and M. Danielewski, "Modeling Non Equilibrium Potentiometry to Understand and Control Selectivity and Detection Limit", ECS Transactions, 2009, 19, 219-224.
[176]  T. Sokalski, W. Kucza, M. Danielewski, A. Lewenstam, "Time-Dependent Phenomena in the Potential Response of Ion-Selective Electrodes Treated by the Nernst-Planck-Poisson Model. Part 2: Transmembrane Processes and Detection Limit" Analytical Chemistry 2009, 81, 5016–5022.
[177]  U. Mattinen, J. Bobacka, A. Lewenstam, "Solid-Contact Reference Electrodes Based on Lipophilic Salts", Electroanalysis 2009, 21, 1955-1960.
[178]  E. Jacobs, J. W. Naskalski, N. Fogh-Andersen, Ch. Ritter, A. Lewenstam, A. Maas, G. Mager, A. O. Okorodudu, "Blood Glucose Point-of-Care Testing Quality Assessment and Harmonization With Central Laboratory Assays", Point of Care 2009, 8, 82-86.
[179]  Z. Mousavi, J. Bobacka, A. Lewenstam and A. Ivaska, "All-solid-state potassium ion-selective electrode based on conducting polymer doped with carbon nanotubes as the ion-to-electron transducer", Journal of Electroanalytical Chemistry, 633 (2009) 246-252.
[180]  Lisak, G., Sokalski, T., Bobacka, J., Harju, L., Lewenstam, A., A study on lowering the detection limit with solid-state lead-selective electrodes, Talanta, 83 (2010), 436–440.
[181]  Jasielec JJ., Sokalski, T., Filipek R., Lewenstam, A., Comparison of different approaches to the description of the detection limit of ion-selective electrodes Electrochimica Acta, 55 (2010), 6836–6848.
[182]  Paczosa-Bator, B., Piech R., Lewenstam, A:, Talanta, 81 (2010) 1003–1009. Determination of the leaching of polymeric ion-selective membrane components by stripping voltammetry Talanta, 81 (2010), 1003–1009.
[183]  Lisak, G., Wagner, M., Kvarnström, C., Bobacka, J., Ivaska, A., Lewenstam A:, Electrochemical behaviour of poly(benzopyrene) films doped with eriochrome black T as a Pb2+-sensitive sensors, Electroanalysis, 22 (2010), 2794-2800.
[184]  Anastasova-Ivanova, S., Mattinen, U., Radu, A., Bobacka, J., Lewenstam, A., Migdalski J., Danielewski M., Diamond, D., Development of miniature all-solid-state potentiometric sensing system Sensors and Actuators B, 146 (2010) 199–205.
[185]  Radu, A., Anastasova-Ivanova, S., Paczosa-Bator, B., Danielewski, M., Bobacka, J., Lewenstam, A, Diamond, D., Diagnostic of functionality of polymer membrane-based ion selective electrodes by impedance spectroscopy, Analytical Methods, 2 (2010), 1490–1498.
[186]  Peshkova, M., Sokalski, T., Mikhelson, K., Lewenstam, A. Blomquist, M., Significant improvement of lower limit of the ion-selective electrodes by optimizing galvanostatic polarization, Bulletin of the St. Petersburg University, 4 (2010), 106-117.
[187]  Lewenstam, A. Non-equilibrium potentiometry—the very essence, Journal of Solid State Solid State Electrochemistry 4 (2011) , 15–22.

Publications: Books/Book Chapters

[1]  Contemporary electroanalytical chemistry Plenum Press, New York and London, 1990; with: A.Ivaska and R.Sara (editors), ISBN 0-306-43818-6;
[2]  Unique Magnesium-Sensitive Ion Selective Electrodes Blackwell Scientific Publications, Oxford, London, Edinburgh, Boston, Melbourne, Paris, Berlin, Vienna, 1994, with B.M.Altura (editor), ISSN 0085-591X;
[3]  Stojek Z. Lewenstam A., (editors) ElectroAnalysis ESEAC 2002 (9th International Confetence held in Krakow, Poland 9-13 June 2002) in: Electroanalysis, 2003, 15(5-6) pp.271
[4]  ESEAC 2002 : 9-th International Conference on Electroanalysis : 9-13 June 2002, Cracow, Poland : Book of Abstracts. Eds. Janusz Golas, Andrzej Lewenstam, Zbigniew Stojek, Andrzej Bobrowski ; European Society for ElectroAnalytical Chemistry ; Society for ElectroAnalytical Chemistry. Kraków: University of Mining and Metallurgy, 2002, pp. 279;
[5]  A.Lewenstam, "Bohr's correspondence principle", in: The correspondence principle in physics and the development of Science", pp.21 35, publisher: Scientific Publishing Comp. (PWN), Poland, 1974, (in Polish);
[6]  A.Lewenstam, "On the reduction in modern chemistry", in: "Technology of Science", pp.5 9, publisher: Plock Scientific Society, Poland, 1977, (in Polish);
[7]  A.Lewenstam and J.M.Zytkow, "Models of Atom comments on the development of knowledge", in: "The relations between the theories and the development of Science", pp.27 47, publisher: Polish Academy of Science Ossolineum, Poland, 1978, (in Polish);
[8]  J.M.Zytkow and A.Lewenstam, "The translation and comparability of the theories divided by scientific revolution", in: "The relations between the theories and the development of Science", pp.81-101, publisher: Polish Academy of Science Ossolineum, Poland, 1978, (in Polish);
[9]  A.Lewenstam, "The concretization procedure critical analysis", in: "Technology of Science", pp.34 42, publisher: Plock Scientific Society, Poland, 1979, (in Polish);
[10]  A.Lewenstam, "The last talks", in: "Scientific discovery", Krajewski W and Strawinski W, Eds, p.45-50, publisher: Semper, Warsaw, 2003, ISBN 83-89100-22-3, (in Polish);
[11]  Bobacka, J., Lewenstam, A., Ivaska, A., All-solid-state ion sensors using conducting polymers as ion-to-electron transducers, in: S.K. Aggarwal, N. Gopinath and J.V. Kamat (eds.), International Conference on electroanalytical chemistry and allied topics (ELAC-2004), January 18–23, 2004, Goa, Indian Society for ElectroAnalytical Chemistry (ISEAC), Mumbai, India, ISBN 81-901950-0-X, p. 57-70.
[12]  B Paczosa-Bator and A.Lewenstam, "Synthesis and electrochemical characteristics of polypyrrole films doped with asparagines and glutamine" in: "At the boundary of chemistry and biology", H. Koroniak and J. Barciszewski Eds., Vol XI 2004, pp. 231-239. publisher. University of Poznan, Poland, ISBN: 83-232-1494-8.
[13]  B. Paczosa-Bator, T. Blaz, J. Migdalski and A. Lewenstam, "Conducting polymer films modified by active ligands as model to study propagation of biological membrane potential with time" in: "Development in production and use of new agrochemicals", eds. H. Gorecki, Z. Dobrzanski, P. Kafarski; publisher: Prague–Brussels : Czech-Pol Trade, 2005, (Chemistry for Agriculture, ed. Adam Pawełczyk), vol. 6, pp. 830–838.
[14]  A. Lewenstam, "Clinical analysis of blood gases and electrolytes by ion-sensitive sensors", in: Electrochemical Sensor Analysis (Comprehensive Analytical Chemistry vol. 49); S. Alegret, A. Merkoci (Eds) Elsevier, Amsterdam, The Netherlands; Oxford, UK; 2007; Chapter 1, pp. 5-24. ISBN: 978-0-444-53053-0, ISBN CD-ROM: 978-0-444-53133-9; ISSN: 0166-526X.
[15]  N. Blomqvist-Kutvonen, J. Ost and A. Lewenstam, "Measurement of ionized Mg2+ in human blood by ion-selective electrode in automatic blood electrolyte analyzer" in: Electrochemical Sensor Analysis (Comprehensive Analytical Chemistry vol. 49); S. Alegret, A. Merkoci (Eds) Elsevier, Amsterdam, The Netherlands; Oxford, UK; 2007; Procedure 1, pp. e5-e11. ISBN: 978-0-444-53053-0, ISBN CD-ROM: 978-0-444-53133-9; ISSN: 0166-526X.
[16]  J. Bobacka, M. Vazquez, Fredrik Sundfors, K. Mikhelson, A. Lewenstam and A. Ivaska, " Determination of Ca(II) in wood pulp using a calcium-selective electrode with poly(3, 4-ethylenedioxythiophene) as ion-to-electron transducer", in: in: Electrochemical Sensor Analysis (Comprehensive Analytical Chemistry vol. 49); S. Alegret, A. Merkoci (Eds) Elsevier, Amsterdam, The Netherlands; Oxford, UK; 2007; Procedure 4 , pp. e25-28. ISBN: 978-0-444-53053-0, ISBN CD-ROM: 978-0-444-53133-9; ISSN: 0166-526X.